跳到内容
CableSimPro文档

电热耦合参考(英文)

One PluginService, project store, catalog, permission/lock model and artifact API. The new first-party adapter has a fixed host-owned worker entry; unrelated adapters retain their existing bytes, versions and digests. The new inert JSON record under plugins/releases is combined with the legacy registry by the same Catalog, including global duplicate-ID/command checks. It is not another runtime or an external package installer. Nothing is installed or imported from an arbitrary manifest path.

Inputs and physical scope

Three identical single-core six-layer cables and homogeneous soil. The existing Gmsh 19-domain mesh and scikit-fem P1 thermal assembly are reused. Each material's thermal conductivity is constant. Ground, sides and bottom are all at the saved ambient temperature, with the same finite-domain S=4/8/16 and mesh16/24/32 options.

The project must contain an explicit R20 in ohm/km. Unlike the legacy demo, this plugin never estimates R20 from area or material resistivity. The saved Scenario supplies RMS conductor-to-screen U0 (kV), frequency, relative permittivity, tan-delta, AC-extra factor, screen-loss factor, temperature limit and operating current. Arguments supply alpha20 (/K), the two metal conductivities and a mandatory human-written coefficient-basis note. A separate acknowledgement is required. These are user declarations, not authenticated approval or manufacturer certification.

With mean conductor temperature Tc,j, define:

  • Rac,j [ohm/m] = R20 [ohm/km]/1000 * (1 + ac_extra) * (1 + alpha20*(Tc,j - 20)).
  • Pc,j [W/m] = I² * Rac,j, uniform over the equivalent conductor domain.
  • Ps,j [W/m] = screen_loss_factor * Pc,j, uniform over the metal-screen domain.
  • C [F/m] = 2piepsilon0*epsilon_r / log(r_insulation_outer/r_insulation_inner).
  • Pd,j [W/m] = 2pifC(1000U0)²tan_delta, distributed proportionally to 1/r² in that phase's insulation, normalized to the declared total on the polygon mesh.

U0 is already phase-to-screen RMS voltage: do not divide by sqrt(3). All three loss components enter their own physical layers. The fixed screen ratio does NOT model induced screen current or its resistance/temperature feedback; skin/proximity and bonding-dependent loss factors are NOT calculated. No armouring, soil drying, backfill, ducts, contact resistance, axial conduction, load history or thermal property nonlinearity is included. This is not complete IEC60287 or EM FEM.

Resistance uses the area-average conductor temperature. The temperature limit uses the maximum conductor nodal temperature. This distinction is included in results and verified from the field. Individual strands and current redistribution inside a nonisothermal conductor are not resolved.

Computation and why the reduced feedback is exact for this model

Let A be the thermal FEM matrix, B the nine normalized source vectors, and U=A⁻¹B on free DOFs. These nine real FEM solutions are not an imported thermal-network approximation. Define Ueff=Uconductor + lambdaUscreen and u0=Pdsum(Udielectric). With conductor averaging weights Bc, H=Bcᵀ Ueff and t0=Bcᵀ u0. For balanced current, g=I²*R20ac and the three conductor powers satisfy:

(identity - g*alpha20*H) p = g * (1 + alpha20*(Ta + t0 - 20)).

For constant thermal conductivities and the stated linear mean-temperature resistance law, this is an exact elimination of the full discrete thermal problem, not a surrogate fit. Every accepted final state also runs a bounded Picard feedback iteration and cross-checks its power with the small-system solution. The native suite independently iterates the full sparse thermal system, without using H, and compares all nodal temperatures.

Reject negative/nonfinite solutions and feedback spectral radius >=1-1e-8. A failed final Picard check never becomes success. The residual from Au-Bp is reported at free DOFs and summed at Dirichlet boundaries. This is a discrete reaction-based energy check, not independently measured heat flux.

Two explicit operations

operating-point: uses Scenario.operating_current_a. It may report an over-limit state up to150°C, but ampacity_a is null. Higher accepted-point temperatures are rejected as outside this reference model's declared range. Zero current still includes dielectric heating when voltage and tan-delta are nonzero. No fabricated all-zero loss assumption.

ampacity: finds the common phase current at which the hottest conductor reaches the saved limit. Bracket between zero current and a stable high trial, bounded by maximum_search_current_a (default3000A). Reject a zero-current over-limit state, unbracketed interval, unstable feedback or nonconvergence. Bisection returns the feasible lower endpoint, not an arbitrary last iterate. Both endpoints, trial history, <=0.01A bracket width and <=0.005K lower-end temperature shortfall are saved. These tolerances describe the numerical root, NOT the accuracy of the physical model.

Domain comparison is not an error certificate

An optional strictly larger domain is remeshed and independently solved at the same mesh setting and electrical inputs. It has its own inverse current, bracket, field, mesh and iteration evidence. Report the pairwise current change and the larger-domain peak at the original current. Both remain bound to the same saved Scenario.

within_pairwise_tolerance only compares two numbers against a user-selected drift threshold (default0.5%). mesh_independence_certified and infinite_domain_accuracy_certified are always false. The primary ampacity is NOT silently replaced with the comparison result. A small pairwise change alone is not a bound on remaining truncation error. Nor does this run establish mesh independence, experimental accuracy, regulatory compliance or a production rating.

Artifacts and failure boundaries

Primary: buried.msh, field.json (existing buried-field/1), temperature.vtu, thermal.json (new electrothermal-reference/1), iteration.json. Optional: comparison.msh, comparison-field.json, comparison.json. VTU/JSON nodal values agree. File length/SHA-256 are checked by host and field viewer. Before persisting success, the host verifies R(T), I²R, screen/dielectric losses, total heat, electrical input binding, field means/peaks, boundary temperature, domain extents, root bracket and comparison binding. Missing or incorrect evidence fails rather than silently falling back to the previous solver.

The host does not modify project parameters or automatically promote this result to its existing ampacity run. No separate project DB, global navigation or third-party remote-code loader is introduced. A fixed process is fault isolation, not OS sandboxing.

Reproduction

Use a separate environment. Install backend requirements and optionally only plugins/requirements-electrothermal.txt (full CAD environment not required for this new plugin). The full regression workflow still tests Windows CAD clean exits.

python scripts/plugin_sdk.py verify
python scripts/seal_plugin_catalog.py
python -m pytest plugin-tests/test_electrothermal.py

Numerical examples use explicitly labelled synthetic test inputs, not manufacturer records. Exact source SHA, platform environment, JUnit and browser screenshots accompany CI evidence. Local Python3.13 numerical tests do not replace Windows or pinned-host acceptance.

Primary technical references (checked during this increment)

The reduction, validation rules and solver acceptance thresholds above are our implementation choices. None of these upstream projects certifies this adapter.


本页由仓库文件 docs/plugins/ELECTROTHERMAL_REFERENCE.md 生成,修改请编辑该文件。

本页目录